FRIDAY, Feb. 22 (HealthDay News) -- The current standard test for measuring blood sugar control in people with diabetes gives inaccurate results for people on kidney hemodialysis, a U.S. study finds.

Hemodialysis, used to treat patients with kidney failure, involves cleansing blood by circulating it through an artificial kidney machine.

This Wake Forest University Baptist Medical Center study of 307 diabetes patients -- 258 with end-stage kidney disease and 49 who didn't have kidney failure -- found that the HbA1c test underestimated true glucose control in hemodialysis patients. The report is published in the journal Kidney International.

These results suggest that the almost 200,000 diabetic hemodialysis patients in the United States who use this test may not be receiving optimal care for their blood sugar, study senior author Dr. Barry J. Freedman, a professor of internal medicine and nephrology, said in a prepared statement.

Diabetic patients on hemodialysis who believe their blood sugar levels are in the ideal range may actually have unacceptably high blood sugar levels, he noted.

"This was a surprise to the nephrology community. The test we've all come to accept as the gold standard has proven to be inaccurate in this patient population," Freedman said.

He said doctors and patients need to be aware that the HbA1c test underestimates glucose control.

This study was funded by Asahi Kasei Pharma Corp. of Japan, which makes a newer test that measures the amount of blood sugar that's reacted with albumin, a protein in the plasma. The GA (glycated albumin) test is not available in the United States.

More information

The National Kidney Foundation has more about hemodialysis.

 

Copyright © 2008 ScoutNews, LLC. All rights reserved.


TOP CARS
  • Chevrolet Impala 2007, 3.5L, 6 CYL., Automatic, FI, Dark Silver Metallic. Call (252)335-0724...(more)
  • * Monthly payment rate based on 6,9% annual percentage rate for 72 months, with approved credit, cash or trade down payment, $...(more)
  • * Monthly payment rate based on 6,9% annual percentage rate for 72 months, with approved credit, cash or trade down payment, $...(more)
- View All Top Cars -
- Place An Ad -

The Daily Advance | Weather | Sports | Albemarle Life | Business | Opinion | Classifieds | Site Map
Cars | Jobs | Homes

Copyright Tue Dec 02 08:11:37 EST 2008 The Daily Advance All rights reserved. - The Daily Advance - Our Partners

By using this service, you accept the terms of our visitor agreement and privacy policy
Registered site users, you may edit your profile.
Having trouble? Visit our help & FAQ